Home Page Home Page ČeskyEnglish
Home Page
About Us
Products
Downloads


Primary current 1000 A


Selection Reduce

Secondary
Output
Accuracy Class
Current [A]
[VA]
For measurement
For protection



*
Code
 Type
 Sec.
current
Mount. *
 Output
Acc. *
Class
Ext. *
FS *
 Price
 Details
1630
CLA 3.1 
1
A
busbar
2.5
VA
0,1
120%
15
102.86 € 
2000
CLB 10 
1
A
busbar
5
VA
0,2
120%
10
104.08 € 
2139
CLA 3.1 
1
A
busbar
1.5
VA
0,2S
120%
20
114.29 € 
1028
CLB 5.91 
1
A
busbar
5
VA
0,5
120%
10
40.73 € 
1248
CLB 6.91 
1
A
busbar
10
VA
0,5
120%
10
40.90 € 
0461
CLA 3.1 
1
A
busbar
15
VA
0,5
120%
5
45.31 € 
1289
CLB 10 
1
A
busbar
15
VA
0,5
120%
5
54.82 € 
1380
CLB 5.91 
1
A
busbar
15
VA
0,5
120%
5
40.73 € 
1675
CLA 3.2 
1
A
busbar
30
VA
0,5
120%
5
47.59 € 
1818
CLA 3.1 
1
A
busbar
10
VA
0,5S
150%
10
62.45 € 
1811
CLB 6.91 
1
A
busbar
10
VA
0,5S
120%
5
52.24 € 
0683
CT 
1
A
busbar
5
VA
1
120%
10
38.86 € 
2206
CLB 5.91 
1
A
busbar
10
VA
1
120%
5
32.45 € 
1238
CLB 10 
1
A
busbar
15
VA
1
120%
5
45.96 € 
1656
CLB 5.91 
1
A
busbar
15
VA
1
120%
5
32.45 € 
1382
CLB 6.91 
1
A
busbar
15
VA
1
120%
5
32.45 € 
0372
CLA 3.1 
1
A
busbar
30
VA
1
120%
5
40.33 € 
1782
CLB 10 
1
A
busbar
30
VA
1
120%
5
46.53 € 
1352
CLB 6.92 
1
A
busbar
30
VA
1
120%
5
33.88 € 
1348
CT 
1
A
busbar
30
VA
1
120%
10
37.39 € 
0560
CT 
1
A
busbar
30
VA
1
120%
5
39.71 € 
0599
CLA 3.1 
1
A
busbar
35
VA
1
120%
5
40.90 € 
0239
CLA 3.2 
1
A
busbar
60
VA
1
120%
5
42.53 € 
2200
CLA 3.2 
1
A
busbar
5
VA
5P
120%
10
44.49 € 
2282
CLA 3.2 
1
A
busbar
10
VA
5P
120%
10
47.55 € 
1250
CLA 3.2 
1
A
busbar
30
VA
5P
120%
5
45.71 € 
1766
CLA 3.2 
5
A
busbar
5
VA
0,1
120%
25
100.00 € 
1343
CLA 3.1 
5
A
busbar
15
VA
0,1
120%
5
111.02 € 
2207
CLB 5.92 
5
A
busbar
10
VA
0,2
120%
10
80.82 € 
2108
CLA 3.2 
5
A
busbar
10
VA
0,2S
120%
10
103.67 € 
2075
CLA 3.2 
5
A
busbar
15
VA
0,2S
120%
10
106.12 € 
1363
CLA 3.1 
5
A
busbar
5
VA
0,5
120%
15
34.98 € 
1201
CLB 10 
5
A
busbar
5
VA
0,5
120%
5
40.45 € 
1233
CLB 5.91 
5
A
busbar
5
VA
0,5
120%
5
31.47 € 
1159
CLB 6.91 
5
A
busbar
5
VA
0,5
120%
5
31.59 € 
0483
CLA 3.1 
5
A
busbar
10
VA
0,5
120%
10
34.20 € 
1050
CLB 10 
5
A
busbar
10
VA
0,5
120%
5
42.33 € 
1237
CLB 5.91 
5
A
busbar
10
VA
0,5
120%
5
30.53 € 
1219
CLB 6.91 
5
A
busbar
10
VA
0,5
120%
5
31.59 € 
0174
CLA 3.1 
5
A
busbar
15
VA
0,5
120%
5
34.98 € 
0603
CLB 10 
5
A
busbar
15
VA
0,5
120%
5
42.33 € 
0864
CLB 5.91 
5
A
busbar
15
VA
0,5
120%
5
31.47 € 
0940
CLB 6.91 
5
A
busbar
15
VA
0,5
120%
5
31.59 € 
1056
CLA 3.1 
5
A
busbar
20
VA
0,5
120%
5
35.22 € 
1148
CLA 3.1 
5
A
busbar
30
VA
0,5
120%
5
36.78 € 
0198
CLA 3.2 
5
A
busbar
30
VA
0,5
120%
5
36.78 € 
0604
CLB 10 
5
A
busbar
30
VA
0,5
120%
5
42.65 € 
0902
CLB 5.92 
5
A
busbar
30
VA
0,5
120%
5
31.92 € 
0971
CLB 6.92 
5
A
busbar
30
VA
0,5
120%
5
32.12 € 
0903
CLB 5.92 
5
A
busbar
45
VA
0,5
120%
5
31.92 € 
1359
CLB 5.91 
5
A
busbar
5
VA
0,5S
120%
10
40.20 € 
2170
CLB 6.91 
5
A
busbar
5
VA
0,5S
120%
10
40.33 € 
1227
CLA 3.1 
5
A
busbar
10
VA
0,5S
120%
10
43.76 € 
1725
CLA 3.1 
5
A
busbar
10
VA
0,5S
150%
10
48.12 € 
1374
CLB 10 
5
A
busbar
10
VA
0,5S
120%
5
51.06 € 
1858
CLB 10 
5
A
busbar
10
VA
0,5S
150%
5
55.14 € 
1335
CLB 5.91 
5
A
busbar
10
VA
0,5S
120%
5
40.20 € 
1263
CLB 6.91 
5
A
busbar
10
VA
0,5S
120%
5
40.33 € 
2284
CLB 10 
5
A
busbar
15
VA
0,5S
120%
5
52.78 € 
2041
CLB 5.91 
5
A
busbar
15
VA
0,5S
120%
5
41.84 € 
2283
CLB 6.91 
5
A
busbar
15
VA
0,5S
120%
5
41.84 € 
2054
CLB 5.92 
5
A
busbar
30
VA
0,5S
120%
5
58.78 € 
0532
CLA 3.1 
5
A
busbar
15
VA
1
120%
5
31.18 € 
0618
CLB 10 
5
A
busbar
15
VA
1
120%
5
35.51 € 
0876
CLB 5.91 
5
A
busbar
15
VA
1
120%
5
25.31 € 
0950
CLB 6.91 
5
A
busbar
15
VA
1
120%
5
25.31 € 
0182
CLA 3.1 
5
A
busbar
30
VA
1
120%
5
31.18 € 
0409
CLA 3.2 
5
A
busbar
30
VA
1
120%
10
32.86 € 
0619
CLB 10 
5
A
busbar
30
VA
1
120%
5
35.80 € 
0877
CLB 5.91 
5
A
busbar
30
VA
1
120%
5
26.12 € 
0982
CLB 6.92 
5
A
busbar
30
VA
1
120%
5
26.12 € 
0917
CLB 5.92 
5
A
busbar
45
VA
1
120%
5
26.12 € 
0206
CLA 3.2 
5
A
busbar
60
VA
1
120%
5
32.86 € 
0918
CLB 5.92 
5
A
busbar
60
VA
1
120%
5
26.53 € 
1239
CT 
5
A
busbar
15
VA
10P
120%
10
60.41 € 
0634
CLB 10 
5
A
busbar
15
VA
3
120%
5
34.78 € 
0961
CLB 6.91 
5
A
busbar
15
VA
3
120%
5
23.67 € 
0190
CLA 3.1 
5
A
busbar
30
VA
3
120%
5
29.51 € 
0635
CLB 10 
5
A
busbar
30
VA
3
120%
5
35.10 € 
0890
CLB 5.91 
5
A
busbar
30
VA
3
120%
5
23.67 € 
0995
CLB 6.92 
5
A
busbar
30
VA
3
120%
5
20.16 € 
0214
CLA 3.2 
5
A
busbar
60
VA
3
120%
5
31.18 € 
0931
CLB 5.92 
5
A
busbar
60
VA
3
120%
5
23.67 € 
0679
CLB 10 
5
A
busbar
5
VA
5P
120%
10
38.37 € 
2109
CLA 3.2 
5
A
busbar
10
VA
5P
120%
10
39.18 € 
0578
CLA 3.2 
5
A
busbar
15
VA
5P
120%
5
38.37 € 

LEGEND:

  • Code = Supply number to be used in orders;
  • Ratio = Transformation ratio = primary current/secondary current;
  • Mount. = Type of mounting;
  • Acc. Class = Accuracy class;
  • Ext. = Extension;
  • FS = Instrument security factor (ev. accuracy limit factor for protective transformers).

Note: Records are ordered by following keys: primary current, secondary current, accuracy class, rated output,
              type of transformer.




měřicí transformátory, spol. s r.o., Podolí 474, 664 03 Podolí - mtbrno@mtbrno.cz
Phone: +420 545 576 049, +420 533 424 138
New address as of 1.1.2016