Home Page Home Page ČeskyEnglish
Home Page
About Us
Products
Downloads


Product listing including prices



1. Searching forms



2. Searching step by step

Searching by primary current values [A]:

1 - 5 - 10 - 12.5 - 15 - 20 - 25 - 30 - 40 - 50 - 60 - 75 - 100 - 125 - 150 - 200
250 - 300 - 400 - 500 - 600 - 750 - 800 - 1000 - 1250 - 1500 - 2000 - 2500 - 3000



3. Current Transformers by size

Fulfilment Maximum
inside aperture
Transformer
width
60 mm
Transformer
width
80 mm
Transformer
width
90 mm
Transformer
width
130 mm
Base - CLB 0.6        1-10 A CLA 1 S   1-15 A CLB 0.9       1-15 A -
- - CLA 1  10-250 A - -
Busbar 20 x 10 mm CLB 2.6     50-500 A - - -
Ø     22 mm CLB 22R.6 50-600 A - - -
30 x 10 mm CLB 3.6     50-500 A - CLB 3.9     50-300 A -
32 x 10 mm CLB 32.6   75-750 A - - -
40 x 10 mm CLB 4.6   100-800 A CLA 2  50-800 A CLB 4.9     50-800 A -
50 x 10 mm - - CLB 5.9   75-1000 A -
60 x 10 mm - - CLB 6.9 125-1000 A -
80 x 10 mm - - - CLA 3   300-2000 A
100 x 10 mm - - - CLB 10 400-3000 A




Transformer CLA Transformer CLB
Click - ZOOM



Specifications and Application type CLA a CLB


  • highest voltage for equipment 720 V
  • power frequency withstand voltage 3 kV
  • rated frequency 50 - 60 Hz
  • rated primary current I1n = 1 - 3000 A
  • rated short-time thermal current Itherm = 60x I1n (1 sec)
  • rated dynamic current Idyn = 150x I1n

A completely enclosed mini current transformer, most appropriate for use in low-voltage switchboard plants for indoor installation. It can be used for the connection of ammeters and current circuits of meters, protective and other measuring devices.

Core and secondary winding are housed in a black case of self-extinguishing material. Insulation class E, max. constant temperature 120ºC.

The secondary terminals are sealable.

The transformer can be mounted in all position on busbars of square or round cross-section cross-section. It can also be mounted on the specially made frames by means of four screws in such a way that the primary conductor freely passes through the transformer hole.

The transformers are made according to the standards ČSN 35 1360, ČSN 35 1301, ČSN EN 60044-1, ČSN EN 61869-2 (Czech Standards) and of course IEC 60044-1 and IEC 61869-2. Each transformer is thoroughly tested in the factory. The factory test certificate is provided upon request.




měřicí transformátory, spol. s r.o., Podolí 474, 664 03 Podolí - mtbrno@mtbrno.cz
Phone: +420 545 576 049, +420 533 424 138